How Accurate Is a Digital Twin? The Science Behind Measuring Anatomy
Discover the science behind PVCT's anatomical accuracy, from DICOM voxel measurements and 3D reconstruction to independent validation and clinical benchmarks.


When we set out to build PVCT, one question kept coming back to us: how do we know that what we reconstruct is actually accurate?
A three-dimensional model can look remarkably convincing. But in healthcare, visual appeal is not the measure of success. If a digital representation is to become useful in clinical practice, its dimensions must be dependable too. The difference between an organ that looks right and one that measures right can be significant.
This is why we believe anatomical accuracy deserves as much attention as the reconstruction itself.
An interesting aspect of CT imaging is that it is not simply a collection of pictures. Every scan is a three-dimensional dataset made up of tiny units called voxels. Each voxel has a physical position and dimensions, recorded in the DICOM data. Together, these provide the spatial foundation from which anatomical measurements can be derived.
In PVCT, our approach is to retain that connection throughout the reconstruction process. Anatomical structures are identified through AI-based segmentation, assembled into 3D representations and quantified using the original scan geometry. Measurements such as organ volume, length and surface dimensions are derived from the underlying data, rather than estimated from how the final model happens to look. We also compare voxel-based volume calculations with the reconstructed surface to identify discrepancies that may arise during reconstruction.
But accuracy is not determined by the algorithm alone.
The quality of the original scan matters. Slice thickness, image resolution and acquisition settings can all influence how clearly anatomical boundaries are captured. At the edges of organs, a single voxel may contain a mixture of different tissues, making the exact boundary difficult to establish. Variations in anatomy and pathology add further complexity. No reconstruction system can recover a level of detail that the original scan never captured.
So how do we establish whether the measurements can be trusted?
Our validation framework approaches this at three levels, each designed to examine a different aspect of accuracy:
Physical phantom validation – Is the geometry right?
We use physical objects with precisely known dimensions and volumes, scan them and compare the reconstructed measurements against their actual values. This helps isolate errors arising from the scanner, data processing and reconstruction stages.
Expert reference validation – Is the anatomy right?
Patient scans are independently annotated by radiologists, and PVCT's reconstructed anatomy is compared against these expert references. Since even experienced radiologists may differ in how they delineate anatomical boundaries, the evaluation also considers the range of variation between experts.
Prospective clinical validation – Does it hold up in real hospital settings?
This takes the evaluation into clinical environments, where PVCT's output can be assessed against expert measurements and actual clinical workflows. The planned multi-centre programme will initially focus on CT imaging of the lungs and kidneys, examining three aspects: agreement with expert annotations, the time required to produce a usable model, and the perceived usefulness of the models and their measurements to clinicians.
PVCT is currently a working prototype. While it has been tested on real DICOM data, accuracy figures validated across hospitals have yet to be established. The multi-centre clinical validation programme is planned to begin in January 2027.
For us, this is an essential part of building the platform responsibly. A digital anatomical twin must be more than a detailed visual representation. Its measurements must be traceable to the original imaging data, its limitations must be recognised, and its accuracy must be tested against independent evidence.
But what does accuracy actually look like when measured in numbers? In our next article, we will take a closer look at the benchmarks behind this evaluation: from Dice similarity and boundary-distance measurements to organ-volume errors and agreement between expert assessments. We will also examine why even experienced radiologists can arrive at different measurements of the same anatomy, and what that means when evaluating an AI-based reconstruction system.
Because ultimately, the credibility of a digital twin will depend not just on how closely it resembles the patient, but on how well its measurements stand up to scientific scrutiny.
That is the standard we are working towards at Cresendos.